OCGT and Reciprocating Engines

9 unique locations (220 components)

Active MW: 17191.57 MW
Inactive MW: 3505.09 MW
2 South Wardpark Place, Wardpark, Cumbernauld, Glasgow, North Lanarkshire, G67 3HX (26 components) Geocoding Needed
β€’ New build gas generator
β€’ Operational Reciprocating Engine
β€’ Operational gas reciprocating engine.
Reciprocating engines OCGT and Reciprocating Engines GREENSPAN NIFTY FIFTY LIMITED Existing Generating CMU Wardpark Alpha Wardpark Alpha +14 more G67
Active β€’ 2028-29 (T-4), 2027-28 (T-4) ...
60.69 MW
Adjacent to Seal Sand Bulk Storage Facility, Seal Sands, Stockton-on-Tees, Cleveland, TS2 1UB (11 components) Geocoding Needed
β€’ Existing OCGT
β€’ The auxiliary load is minimal (1MW) and have been removed from the metering assessment when calculating the maximum generating output
β€’ The auxiliary load is minimal (1MW) and have been removed from the metering assessment when calculating the maximum generating output.
Active β€’ 2028-29 (T-4), 2027-28 (T-4) ...
439.71 MW
Cowes Power Station, Kingston Road, East Cowes, Isle of Wight, PO32 6JS (23 components) Geocoding Needed
β€’ Cowes 1 - OCGT, fuel is distillate
β€’ Cowes 1 - OCGT, fuel is distillate MSID: 4548
β€’ Cowes 2 - OCGT, fuel is distillate MSID: 4548
Active β€’ 2028-29 (T-4), 2027-28 (T-4) ...
1285.79 MW
Didcot OCGT Power Station, Didcot, Oxfordshire, OX11 7HA (44 components) Geocoding Needed
β€’ Didcot 2 OCGT - Power factor used for conversion of kVA to MW is 1 . Fuel type is distillate MSID: 4032
β€’ Didcot 3 OCGT - Power factor used for conversion of kVA to MW is 1 . Fuel type is distillate MSID: 4032
β€’ Didcot 4 OCGT - Power factor used for conversion of kVA to MW is 1 Fuel type is distillate MSID: 4032
Active β€’ 2028-29 (T-4), 2027-28 (T-4) ...
947.80 MW
Ferrybridge Power Station, Stranglands Lane, Knottingley, West Yorkshire, WF11 8SQ (52 components) Geocoding Needed
β€’ GT5
β€’ GT8
β€’ Unit 4
Active β€’ 2025-26 (T-4), 2024-25 (T-4) ...
Fort Parkway, Heartlands, Birmingham, B24 9QT (22 components) Geocoding Needed
β€’ Existing OCGT
β€’ The auxiliary load is minimal (1MW) and have been removed from the metering assessment when calculating the maximum generating output
β€’ The auxiliary load is minimal (1MW) and have been removed from the metering assessment when calculating the maximum generating output.
Reciprocating engines Open Cycle Gas Turbine (OCGT) OCGT and Reciprocating Engines WHITETOWER ENERGY LIMITED Existing Generating CMU Heartlands Power Heartlands Power +4 more B24
Active β€’ 2028-29 (T-4), 2027-28 (T-4) ...
909.77 MW
Little Barford Power Station, Little Barford, St Neots, PE19 6YT (22 components) Geocoding Needed
β€’ Little Barford 1 CCGT
β€’ Little Barford 1 CCGT MSID: 4052
β€’ Little Barford 1 OCGT . fuel type is distillate MSID: 4052
Active β€’ 2028-29 (T-4), 2027-28 (T-4) ...
6950.00 MW
Unit 2, 105 Abercorn Street, Paisley, PA3 4AT (12 components) Geocoding Needed
β€’ New build gas generator
β€’ Operational reciprocating gas engines
Active β€’ 2028-29 (T-4), 2027-28 (T-4) ...
30.35 MW
Victory Road, Derby, Derbyshire, DE24 9HX (8 components) Geocoding Needed
β€’ Existing OCGT.
β€’ The auxiliary load is minimal (1MW) and have been removed from the metering assessment when calculating the maximum generating output
Open Cycle Gas Turbine (OCGT) OCGT and Reciprocating Engines WHITETOWER ENERGY LIMITED Existing Generating CMU Derby Cogen Ltd Derby Cogen Ltd +5 more DE24
Active β€’ 2028-29 (T-4), 2027-28 (T-4) ...
352.98 MW
Loading map...
Showing 9 locations